> How much acetone - ammoniadichromate mix do you use for a 12x20 inch
> negative, tissue slightly bigger of course.
Witho, the last time I measured the amount of sensitizer used (AD in
50/50 water/isopropanol) is was about 10 mL per 8x10 negative -
tissue ca 9x12. This was applied with a foam brush to give a full
wet flowing coat and then squigeeded after 2 minutes.
Howard
_______________________________________________
Post to the list as PLAIN TEXT only - no HTML
carbon mailing list
carbon@spitbite.org